Service Hotline
4000-662-888A split structure can be adopted, with the refrigeration unit and the box placed separately
The top of the box is perforated for easy lifting of the motor
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow
The central axis adopts a special sealing device to avoid frosting at low temperatures
|
Studio Size? (D*W*H)mm | Dimension(D*W*H)mm | |||
LRHS-1320-PL | 1600mm×2500mm×3300 | 約2500mm×5100mm×3563 |
temperature range | Water temperature +10°C | ||||||
quantity of rainfall | 10—15cm/h | ||||||
raindrop diameter | 0.5—4.5mm | ||||||
Test wind speed | Horizontal wind speed 10-18m/s adjustable | ||||||
raindrop angle | The raindrops have a horizontal direction to 45 ° angle change, and uniformly flutter on the side of the test piece | ||||||
Intensive rainfall | This procedure may be considered when testing large specimens where rainfall and rain blowing devices cannot be used. | ||||||
quantity of rainfall | 2800+30L/m2/h | ||||||
Rain drops cannot be aggregated into a stream, and the dispenser distributes the drip holes in a matrix at 20-25.4mm intervals. | |||||||
Rainfall distance | The drip height should ensure that the final velocity of the water drop is 9m/s | ||||||
Turntable size/carrying capacity | Diameter: φ1000mm, Load: ≥50kg | ||||||
Speed range | 1~5r/min continuously adjustable | ||||||
Workpiece size limitation | Maximum allowable size of test piece: 1000mm×1000mm×1000mm | ||||||
Outer case material | High-quality library boards | ||||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
Insulation material | Rigid polyurethane foam | ||||||
drip tray | Imported high-grade stainless steel SUS304 + aluminum plywood + aluminum profile | ||||||
Controller | Taiwan “Wyland” temperature and humidity controller (7.0 inches, high-definition true color “TFT” LCD touch screen) | ||||||
Heating systems | Nichrome wire heaters | ||||||
temperature sensor | High Accuracy Pt100 Platinum Resistance Temperature Sensors | ||||||
Wind Speed Sensor | Differential pressure air velocity sensor, 4-20mA output | ||||||
security protection | Fan, motor, pump overcurrent overload protection, limit, undervoltage, short circuit, phase loss, over temperature, leakage protection | ||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | 24.5kW |