Service Hotline
4000-662-888A split structure can be adopted, with the refrigeration unit and the box placed separately
The top of the box is perforated for easy lifting of the motor
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow
The central axis adopts a special sealing device to avoid frosting at low temperatures
Model | Studio Size? (D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-6500-LHF | 1600 x 1400 x 2900 (eight components) | 3900×1750×3300 |
temperature range | -50℃~+120℃ | ||||||
Temperature fluctuation | ≤±0.5℃ | ||||||
Temperature uniformity | ≤2.0℃ | ||||||
temperature deviation | ≤±2.0℃ | ||||||
Humidity range | 30%~98%RH | ||||||
Sample Temperature Control Rate | -40°C to 0°C ≥ 3.33°C/min (linear, full load, energized) ≥ 1.66°C/min (linear, full load, energized) for the rest of the temperature range | ||||||
Outer case material | High-quality cold-rolled steel plate, surface plastic spraying treatment | ||||||
Inner box material | Stainless steel plate SUS304 | ||||||
Insulation material | Rigid polyurethane (PU) foam | ||||||
controllers | Japan “UEC” brand temperature and humidity meter, 7-inch high-definition true color LCD touch screen display | ||||||
Refrigeration compressors | BITZER, Germany | ||||||
Cooling method | Two-machine cascade refrigeration | ||||||
Temperature and humidity sensors | High Accuracy Pt100 Platinum Resistance Temperature Sensors | ||||||
security protection | Compressor overpressure/overload, fan motor overload, overall equipment timing, over-temperature, water shortage, short circuit, phase loss, leakage and other protection | ||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | 110.0kW | ||||||
Note: 1、 the above data are measured in the use of ambient temperature of 25 ℃ and well-ventilated conditions 2、Can be customized according to the specific requirements of the user non-standard Photovoltaic wet freezing test chamber etc 3、This technical information is subject to change without prior notice. |