4000-662-888A split structure can be adopted, with the refrigeration unit and the box placed separately
The top of the box is perforated for easy lifting of the motor
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow
The central axis adopts a special sealing device to avoid frosting at low temperatures
Model | Studio Size? (D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-101B-LF | 450×450×500 | 1500×1120×1930 | |
LRHS-225B-LF | 500×600×750 | 1550×1270×2160 | |
LRHS-504B-LF | 700×800×900 | 2000×1470×2290 | |
LRHS-800B-LF | 800×1000×1000 | 1900×1560×2550 | |
LRHS-1000B-LF | 1000×1000×1000 | 2100×1560×2550 |
temperature range | A:-20℃~150℃? ? ?B:-40℃~150℃ C:-60℃~150℃? ? ?D:-70℃~150℃ |
||||||
Temperature uniformity | ≤2℃ (at no load) | ||||||
Temperature fluctuation | ±0.5℃(at no load) | ||||||
heating rate | atmospheric(100KPa)~1KPa | ||||||
pressure deviation | atmospheric~50Kpa:±2Kpa; | ||||||
heating rate | RT~150℃≤60min (at atmospheric pressure and no load) | ||||||
cooling rate | RT~-40℃≤40min (at atmospheric pressure and no load) | ||||||
decompression time | ≤45min(atmospheric~30KPa) | ||||||
Time Setting Range | 1~60000M | ||||||
Air cooling method | Multi-stage diaphragm air heat exchanger | ||||||
Pressure adjustment method | Dynamic pressure equalization method | ||||||
Outer case material | High quality A3 steel plate electrostatic spraying | ||||||
Inner box material | Imported high-grade stainless steel SUS304, pressure layer using thickened stainless steel reinforcement | ||||||
Insulation material | Rigid polyurethane foam + fiberglass | ||||||
Temperature Controller | Imported “UEC” brand temperature meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
Cooling method | Single or double cascade refrigeration | ||||||
Compressor | Tycon, France / BITZER, Germany | ||||||
security protection | Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phase Over-temperature, overall equipment timing, leakage protection, overload and short-circuit protection |
||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | (A)12kW/16kW/20kW/24kW/28kW (B)17kW/22kW/27kW/31kW/35kW (C)20kW/25kW/34kW/38kW/42kW |
||||||
operating environment | 5℃~+28℃ ? ? ? ? ≤85% RH | ||||||
Note: 1、the above data are in the use of ambient temperature of 25 ℃ and well ventilated conditions measured 2、Can be customized according to the specific requirements of the user non-standard high and low temperature low pressure test chamber etc 3、This technical information, subject to change without notice |