Service Hotline
4000-662-888A split structure can be adopted, with the refrigeration unit and the box placed separately
The top of the box is perforated for easy lifting of the motor
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow
The central axis adopts a special sealing device to avoid frosting at low temperatures
Model | Studio Size? (D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-2000D(R15)-LJS | 1000×2000×1000 | Subject to contractual three-view | |
LRHS-4000D(R15)-LJS | 2000×2000×1000 | ||
LRHS-6000D(R15)-LJS | 2000×3000×1000 | ||
LRHS-8000D(R15)-LJS | 2000×2000×2000 |
temperature range | A:-20℃~150℃ ? ? ?B:-40℃~150℃ C:-60℃~150℃ ? ? ?D:-70℃~150℃ |
||||||
Temperature uniformity | ≤2℃ (at no load) | ||||||
Temperature fluctuation | ±0.5℃ (at no load) | ||||||
Humidity range | 20%~98% RH | ||||||
Humidity uniformity | +2% -3% RH | ||||||
Humidity fluctuation | ±2% | ||||||
heating rate | -55℃~125℃ Linear 15℃/min (at no load) | ||||||
cooling rate | 125℃~-55℃ Linear 15℃/min (at no load) | ||||||
Time Setting Range | 1~60000M | ||||||
test hole | Mounted on the left side of the machine for use with external test power or signal cables | ||||||
viewing window | 395 x 395mm (effective field of view) | ||||||
Outer case material | High quality A3 steel plate electrostatic spraying | ||||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
Insulation material | Rigid polyurethane foam + fiberglass | ||||||
Temperature Controller | Imported “UEC” brand temperature and humidity meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
Cooling method | Two-machine cascade refrigeration | ||||||
Compressor | France Tycon/Germany Bitzer/Germany Copeland | ||||||
standard configuration | Equipped with a condensate catch pan and discharged out of the box | ||||||
security protection | Compressor overpressure overload, fan motor overheating, the whole machine under phase / reverse phase Timing, over temperature, leakage protection, overload and short-circuit protection |
||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
operating environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1、 the model in the R represents linear, r represents non-linear, the number in parentheses represents the cooling rate 2、Test data are measured in the use of ambient temperature of 25 ℃ and well ventilated conditions 3、Above parameters are for reference only, can be customized according to user-specific test parameters 4、This technical information, subject to change without notice |