Service Hotline
4000-662-888A split structure can be adopted, with the refrigeration unit and the box placed separately
The top of the box is perforated for easy lifting of the motor
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow
The central axis adopts a special sealing device to avoid frosting at low temperatures
Model | Studio Size? (D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-504-RYGS | 700×800×900 | Subject to contractual three-view | |
LRHS-800-RYGS | 800×1000×1000 | ||
LRHS-1000-RYGS | 1000×1000×1000 |
temperature range | RT+5℃~60℃ | ||||||
Saturated drum temperature | RT+10℃~60℃ | ||||||
Temperature uniformity | ≤2℃ | ||||||
Temperature fluctuation | ±0.5℃ | ||||||
Salt spray deposition | 1~2ml/80 cm2.h(16-hour average) | ||||||
Spraying method | Wall-mounted spray pattern | ||||||
temperature range | RT+10℃~100℃ | ||||||
Humidity range | 85%~98%RH | ||||||
Temperature uniformity | ±2℃ (at no load) | ||||||
Temperature fluctuation | ±0.5℃ (at no load) | ||||||
Humidity fluctuation | ±1% | ||||||
temperature deviation | ±2℃ | ||||||
Humidity Deviation | ±3% | ||||||
temperature range | RT+10℃~200℃ | ||||||
Temperature uniformity | ±2℃ (at no load) | ||||||
Temperature fluctuation | ±0.5℃ (at no load) | ||||||
temperature deviation | ±2℃ | ||||||
Case Material | High quality 316 stainless steel | ||||||
Studio Materials | Imported high-grade stainless steel SUS304 | ||||||
Air-saturated drums | Imported high-grade stainless steel SUS304 | ||||||
Pressurized Air Hose Material | High quality rubber hose | ||||||
Other pipelines | Thickened Fluorosilicone Rubber Tubing | ||||||
Temperature Controller | Imported “UEC” brand temperature and humidity meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
heater | Titanium Heating Tube | ||||||
interrupter | Schneider miniature circuit breakers (to prevent short circuits in control circuits) | ||||||
standard configuration | V-shaped sample holder, round bar, nozzle, funnel, measuring cylinder, mist exhaust pipe | ||||||
security protection | Over-temperature, overall equipment under-phase/reverse phase, overall equipment timing Quick fog discharge indication, end of test, low water level protection, electric leakage and short circuit |
||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | 10.0kW | 13.5kW | 16.0kW | ||||
operating environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1、 the test data are used in the ambient temperature of 25 ℃ and well ventilated conditions measured 2、The above parameters are for reference only, and can be customized according to user-specific test parameters. 3、This technical information, subject to change without notice |